* For any questions, you can contact Customer Service and get a response within 24-hours.
Specification:
1.2M or others
Model
GLS-128000G
GLS-244000G
AC Input
Voltage
100-240V AC
100-240V AC
Input current
0.49A/230V AC
0.49A/230V AC
Frequency
47-63 Hz
47-63 Hz
Efficiency
85% typical
85% typical
Inrush current
36A/230V AC
36A/230V AC
Leakage current
<0.05A/240V AC
<0.05A/240V AC
DC Output
Voltage
12V
24V
Current
0-8000mA
0-4000mA
Rated Power
96W
96W
Ripple&noise
120mvp-p
150mvp-p
Setup rise hold up time
500ms,20ms,50ms/230VAC 500ms,20ms,15ms/115VAC at full load
Protection
Over Load
120%Max, hiccup mode auto recovery after fault condition is removed
Short Circuit
Auto recovery
Environment
Store Temperature
-20-85°C
Wokring Temperature
0--50°C
Operating Humidity
20%-80%RH
Safty
CE
Compliant to EN 60950-1:2006; EN61000-6-3:2001;
EN 55022:2006+A1:2007; EN61000-4-2/-3;
EN61000-6-1:2001; EN55024:1998+A1:2000+A2:2003
RoHs
Free from lead, Cadmium, Mercury, Hexavalent
Chromium and/or PBB &PBDE
others
Product dimension
170*65*40mm
Weight
0.65g/pc(including AC cord)
Packing
20pcs/ctn,45*35*23cm
DC connector size
5.5x2.1, 5.5x2.5. 3.5x1.35 or cigarette lighter socket
Cable length
Notes:
1.Voltage and current can be adjusted by customer requirement.
2.All parameters are specified at 230VAC input, rated load, 27°C 70%RH ambient.